Electrical System SGR
Standby Power Switch
Standby Power switch AUTO
(Guarded position)
- The Standby Power switch controls automatic switching of the
power source to the AC and DC Standby Busses.
- With the switch in the AUTO (Guarded) position and both AC
Transfer Busses powered, the normal source of power to the AC
Standby Bus is Transfer Bus 1 and the normal source of power to
the DC Standby Bus is TR 1, TR 2 and TR 3.
- If the Transfer Busses are not powered, the source of power to
the AC and DC Standby Busses is automatically switched to the
Static Inverter, Battery Bus, Hot Battery Bus,Switched Hot Battery
Bus and Battery.