Electrical System SGR
Standby Power Switch
Standby Power switch AUTO
(Guarded position)
- The Standby Power switch controls
automatic switching of the power source to
the AC and DC Standby Busses.
- With the switch in the AUTO (Guarded)
position and both AC Transfer Busses
powered, the normal source of power to the
AC Standby Bus is Transfer Bus 1 and the
normal source of power to the DC Standby
Bus is TR 1, TR 2 and TR 3.
- If the Transfer Busses are not powered, the
source of power to the AC and DC Standby
Busses is automatically switched to the
Static Inverter, Battery Bus, Hot Battery Bus,
Switched Hot Battery Bus and Battery.