Ground Power selected ON.
- Both BTBs close powering Transfer Bus 1
and Transfer Bus 2 and the associated Main
and Galley busses. GRD POWER
AVAILABLE, SOURCE OFF and TRANSFER
BUS OFF lights extinguish.
- The Ground Service Relays shift and the
Ground Service busses are being powered
by their respective Transfer busses.
- TR 1 is being powered by Transfer Bus 1.
- Tr 2 and TR 3 are being powered by
Transfer Bus 2.
- The Cross Bus Tie Relay is closed and
- DC Bus 1 is powered by TR1, backed up by
TR 2 and TR 3.
- DC Bus 2 is powered by TR 2, backed up by
TR 1 and TR 3.
- The Battery Bus alternate relay has opened
and the Battery Bus is powered by TR 3.
- The DC Standby Bus is powered by TR 1,
TR 2 and TR 3.
- The AC Standby Bus is powered by Transfer
Bus 1.
The sequence of bus switching in the Electrical System SGR is for illustrative purposes only and is not meant to imply an approved procedure.
Electrical System SGR